Benex® III Basic Kit Components
| Item Code | Description | Quantity | |
|---|---|---|---|
![]() |
12.320.00 | Benex® III Basic-Kit consisting of: Benex® III Extractor, 2 Drills per size, 2 Screws per size, 2 Pullropes, Driver Guide, Quadrant Support and Replacement Supports, in Washbasket 1/2 | 1 piece |
![]() |
85.194.11 | Washbasket 1/2 for Benex® III Basic-Kit with Lid and Press Button Lock | 1 piece |
![]() |
12.321.00 | Benex® III Extractor | 1 piece |
![]() |
12.321.30 | Replacement Support front, 12 mm, optional | 1 piece |
![]() |
12.321.34 | Replacement Support rear, 12 mm, optional | 1 piece |
![]() |
12.321.32 | Replacement Support front, 18 mm | 1 piece |
![]() |
12.321.36 | Replacement Support rear, 18 mm | 1 piece |
![]() |
12.321.50 | Pullrope, 48 mm | 2 pieces |
![]() |
12.300.30 | Diamond coated Drill for Screws Ø 1.6 mm (for 12.300.60 and 12.300.70) | 2 pieces |
![]() |
12.300.35 | Diamond coated Drill for Screws Ø 2.1 mm (for 12.300.65 and 12.300.75) | 2 pieces |
![]() |
12.300.47 | Driver Guide, short | 1 piece |
![]() |
12.300.48 | Driver Guide, long, optional | 1 piece |
|
|
12.300.60 |
Screw, Ø 1.6 mm, 10 mm, S = Short | 2 pieces |
|
|
12.300.65
|
Screw, Ø 2.1 mm, 10 mm, SF = Short & Fat | 2 pieces |
|
|
12.300.70
|
Screw, Ø 1.6 mm, 16 mm, L = Long | 2 pieces |
![]() |
12.300.75 | Screw, Ø 2.1 mm, 16 mm, LF = Long & Fat | 2 pieces |
![]() |
12.300.80 | Quadrant support for Benex to bridgeover bigger gaps and for the universal molding |
1 piece |
![]() |
12.321.10 | Benex III Torque Level of tension, The torque gearincludes slip clutch with a maximum loadofapprox. 40 kg, optional optional |
1 piece |
Alveolar-Ridge-Preservation with Benex III
Alveolar Ridge Preservation means the treatment of the dental alveolus after extraction. 3 months after the benex extraction you find a considerably better ridge relation than with conventional gentle extraction finds its successful application in both, private practices and universities. The Benex has achieved an excellent status worldwide as basis for a subsequently successful implantation.

FINALLY THERE: WORLD NOVELTY BenexIII WITH TORQUE FUNCTION
In 2005, BENEX I was presented to the world as a patented innovation at the IDS. For many dentists, this opened up a new era of atraumatic longitudinal extraction. In 2025, 20 years later, Zepf is once again presenting the new version of BENEX III at IDS. A completely revised and protected design now enables easier handling. Once inserted into the extractor, the pull rope is fixed and can therefore be more easily hooked into the screwed-in pull screw. The support surface has been simplified and is easier to position. The new design has made it possible to reduce the number of parts. In particular, the pins that held the previous extractor together have been completely eliminated. Disassembly and assembly is intuitive and simple. The risk of lost parts is significantly reduced.
NEW: Benex TORQUE KEY
The BENEX torque key is a patent-pending world first that makes using BENEX even safer and easier. The learning curve that a new user had to go through with the previous system can be reduced to a minimum. However, not only BENEX III users can use this torque wheel, but also users who are already using previous BENEX extractors from Zepf.
The maximum tensile load is limited to 40 kg. Once this is reached, the torque wheel continues to rotate without increasing the tensile load. The practitioner can therefore wait until the ligaments give way. This is clearly visible thanks to the laser marking on the torque wheel. This means that as the torque wheel is turned further, the force does not increase but the distance is controlled. If the dentist wishes to deliberately ignore this procedure, the torque function can be bypassed with the fix wheel (front thin wheel).
In modern dentistry, the focus is on implantology after tooth extraction. The modified extractor now allows even better gentle, safe and simple extraction of tooth roots in all quadrants. Injury to soft tissue and surrounding bone can be virtually eliminated. With longitudinal extraction, BENEX provides an optimal basis for immediate implant placement. But it is also a valuable aid for subsequent implant placement after extraction. Studies show that after the use of BENEX, the reossification of the extraction socket progresses optimally. This greatly facilitates subsequent implant placement. The new BENEX III is also available in an RKI-compliant wash basket system. This meets the requirement for optimum cleanability and sterilization.
EXTRUSION – CROWN LENGTHENING WITH THE BENEX EXTRACTOR
BENEX is also used in traumatology. Many studies have shown that BENEX can be used in many cases to gently extrude injured teeth. This enables the practitioner to keep an injured tooth in place and to delay a later implant for a possibly young patient until the patient is suitable for it due to age.